What Is Exposure Index?
Exposure index, abbreviated EI, is a sensitivity rating used to judge exposure in a chosen workflow. A cinema camera may let you choose a working EI while keeping a base recording setting fixed. In that case the EI can change the preview and guide the operator toward a different amount of light on the sensor without directly changing that base mode. Other systems handle rating differently. The camera's documentation and a recording test tell you what actually changes.
Separate what the camera records from what the monitor shows
At a fixed base setting, ISO-style numbers on two different pages of a menu may do different jobs. In an EI mode, a viewing transform can compensate for the selected rating to show what editorial might see after exposure correction. Sensor exposure still depends on the light reaching it and camera settings such as aperture, shutter and ND. If you enter one EI into an external incident meter but monitor another, the two checks can appear to disagree.
Changing the amount of exposure trades shadow placement against highlight room in the actual capture. More light can produce a cleaner dark area but can bring highlights closer to saturation. A lower apparent working rating can encourage the operator to give the sensor more exposure. That decision only works if it protects the bright values the scene needs.
Rate a low-key interview against a bright practical
A dark jacket and deep wall color make a studio scene look noisier than expected. The gaffer considers giving the camera more exposure and rating it lower for the preview. The table lamp in the same frame has a bright shade. Before choosing, record the preferred settings, then add a controlled amount of exposure and record again. Use the intended viewing transform to compare the darker surfaces and lamp detail at similar final brightness.
If the lamp loses detail in the brighter capture, dim or control that lamp separately and repeat. If the jacket improvement is small, the original exposure may preserve the more useful highlight margin. Tell editorial the EI and any viewing transform chosen on set so they can reproduce the intended reference without baking a monitor correction into the wrong file.
Retest when the recording mode changes
- Confirm whether the setting changes base sensitivity, metadata, monitoring or a combination on the selected camera.
- Use the correct viewing transform for the log recording and note if it differs for external displays.
- Keep a recorded comparison with shadow texture and real highlights. Evaluate at matched final brightness.
- Record the EI and base mode separately in the camera report when both matter. The same number alone cannot describe the complete setup.